Spare parts for system cables
Plug−in connector properties
Cable end on the controller side
14
l
857
EDSYPFLD EN 8.0
14.6.2 Cable end on the controller side
Characteristic No.
of
pole
s
Rated voltage Core
cross−section
Spare
contact
Number of
contacts required
Plug−in
connector
Power
EWS1016
6 AC/DC 630 V 1.0 ... 2.5 mm
2
EWZ0059 6 P04
EWS1014 8 AC/DC 630 V
0.5 ... 1.0 mm
2
EWZ0060 2
P05
2.5 ... 4.0 mm
2
EWZ0061 4
EWS1015 8 AC/DC 630 V
0.5 ... 1.0 mm
2
EWZ0060 2
P06
6.0 ... 16.0 mm
2
EWZ0062 4
EWS1080 8 AC/DC 630 V
0.5 ... 1.0 mm
2
EWZ0057 4
P07
0.5 ... 2.5 mm
2
EWZ0059 4
EWS0081 9 AC 500 V
1.5 mm
2
– –
Q08
2.5 mm
2
Q09
EWS0083 8 AC 500 V
1.5 mm
2
– –
Q10
2.5 mm
2
Q11
Blower
EWS1002 8 AC/DC 630 V
1.0 ... 2.5 mm
2
EWZ0057 4
J03
1.0 ... 2.5 mm
2
EWZ0059 1
EWS1022 7 AC/DC 630 V 1.0 ... 1.5 mm
2
EWZ0058 7 J04, J05
Feedback
EWS1007 12 AC/DC 125 V 0.14 ... 1.0 mm
2
EWZ0058 9 G06
EWS1011 12 AC/DC 125 V 0.14 ... 1.0 mm
2
EWZ0058 10 G07
EWS1018 17 AC/DC 125 V 0.14 ... 0.5 mm
2
EWZ0058 14 G08
EWS1024 17 AC/DC 125 V 0.14 ... 0.5 mm
2
EWZ0058 16 G09
EWZ0040 9 AC/DC 50 V 0.14 mm
2
– – S01
EWZ0047 9 AC/DC 50 V 0.14 mm
2
– – S02
EWZ0048 15 AC/DC 50 V 0.14 ... 0.5 mm
2
– – S03
EWZ0051 9 AC/DC 50 V 0.14 mm
2
– – S04
EWZ0052 9 AC/DC 50 V 0.14 mm
2
– – S05
EWZ0063 15 AC/DC 50 V 0.14 ... 0.5 mm
2
– – S06
EWZ0049 9 AC/DC 50 V 0.14 mm
2
– – W02
EWZ0070
1)
9 AC/DC 50 V 0.14 mm
2
– – W04
1) When Sub−D plug EWZ0070 is used, an additional free space of 50 mm must be considered due to the depth of the
plug. If the required free space is not available, a connection cable for fixed installation and plug EWZ0049 can be
used in combination with an extension cable suitable for trailing to solve the application.
) Note!
The number of poles refers to the visible poles and not to the number of
physically present contacts or number of cores suitable for connection.
Comentarios a estos manuales