Three−phase asynchronous motors MHxMA: Motor cable selection
MHxMAxx080−xx, MHxMAxx090−xx, MHxMAxx100−12
Star or delta connection − plug, 10−core system cable
7
l
611
EDSYPFLD EN 8.0
7.1.3 Star or delta connection − plug, 10−core system cable
U
V
W
[mm
2
] E94Ax EVF93 E82xV E84AV
E84DS
E84DH
MHxMAxx080−xx
MHxMAxx090−xx
MHxMAxx100−12
(4 × 1.5 + (2 × 0.5) + (4 × 0.5))
U, V, W, PE, ,J
X21
(4 × 2.5 + (2 × 0.5) + (4 × 0.5))
Connection cable
U
V
W
Connection cable
(4 × 1.5 + (2 × 0.5) + (4 × 0.5))
EYP0039AxxxxH07A00
E94Ax
EVF93
E82xV
E84AV
EYP0039AxxxxH07Q08
E84DSxB
E84DHxB
(4 × 2.5 + (2 × 0.5) + (4 × 0.5))
EYP0040AxxxxH08A00
E94Ax
EVF93
E82xV
E84AV
EYP0040AxxxxH08Q09
E84DSxB
E84DHxB
Cable properties
Mechanical/design: ^ 53 Electrical/temperature range: ^ 54 Chemical: ^ 55