Lenze EY System cables and system connectors Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 887
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Technical data
Cable end characteristic
Cable end on the controller side
3
l
57
EDSYPFLD EN 8.0
3.2.2 Cable end on the controller side
This characteristic describes the end of the system cable on the controller side. The plug−in
connectors are designed as pins.
Charac−
teristic
No. of
poles
Rated voltage Core
cross−section
Type
Power
P04
6 AC/DC 630 V 1.0 ... 2.5 mm
2
Plug−in connector with SpeedTec
P05 8 AC/DC 630 V 2.5 ... 4.0 mm
2
Plug−in connector with SpeedTec
P06 8 AC/DC 630 V 6.0 ... 16.0 mm
2
Plug−in connector with SpeedTec
P07 8 AC/DC 630 V 1.0 ... 2.5 mm
2
Plug−in connector with SpeedTec
Q08 10 AC 500 V 1.5 mm
2
Modular plug−in connector 40A
Q09 10 AC 500 V 2.5 mm
2
Modular plug−in connector 40A
Q10 8 AC 500 V 1.5 mm
2
Plug−in connector Q8
Q11 8 AC 500 V 2.5 mm
2
Plug−in connector Q8
Blower
J03 8 AC/DC 630 V 1.0 ... 2.5 mm
2
Plug−in connector with SpeedTec
J04 7 AC/DC 630 V 1.0 ... 1.5 mm
2
Plug−in connector with SpeedTec
J05 7 AC/DC 630 V 1.0 ... 1.5 mm
2
Plug−in connector with SpeedTec
Feedback
G06 12 AC/DC 125 V 0.14 ... 1.0 mm
2
Plug−in connector with SpeedTec
G07 12 AC/DC 125 V 0.14 ... 1.0 mm
2
Plug−in connector with SpeedTec,
coding: 20°
G08 17 AC/DC 125 V 0.14 ... 0.5 mm
2
Plug−in connector with SpeedTec
G09 17 AC/DC 125 V 0.14 ... 0.5 mm
2
Plug−in connector with SpeedTec,
coding: 20°
S01 9 AC/DC 50 V 0.14 mm
2
Sub−D plug
S02 9 AC/DC 50 V 0.14 mm
2
Sub−D plug with locking hook
S03 15 AC/DC 50 V 0.14 ... 0.5 mm
2
Sub−D plug with locking hook
S04 9 AC/DC 50 V 0.14 mm
2
Sub−D plug, large cable entry
S05 9 AC/DC 50 V 0.14 mm
2
Sub−D plug with locking hook, large cable entry
S06 15 AC/DC 50 V 0.14 ... 0.5 mm
2
Sub−D plug
W02 9 AC/DC 50 V 0.14 mm
2
Sub−D plug, (socket)
W04 9 AC/DC 50 V 0.14 mm
2
Sub−D plug, large cable entry(socket)
B02 5 AC/DC 50 V 0.34 mm
2
M12−A connector
Cable end without plug−in connector
A00
) Note!
When Sub−D plug W04 is used, an additional free space of 50 mm must be
considered due to the depth of the plug.
If the required free space is not available, a connection cable for fixed
installation and plug W02 can be used in combination with an extension cable
suitable for trailing to solve the application.