Servo motors: Motor cable selection
MCA motor
MCA20X29
5
l
132
EDSYPFLD EN 8.0
Motors with terminal boxes
U
V
W
[mm
2
]
EVS93
E84AVT
E94AS
E94AM
ECS
MCA20X29−2Fxx
(4 × 10.0 + (2 × 1.0))
U, V, W, PE X105, X107 X24, X25
(4 × 16.0 + (2 × 1.0))
Connection cable
U
V
W
Connection cable
(4 × 10.0 + (2 × 1.0))
E94AS
E94AM
EVS93
ECS
E84AVT
EYP0015YxxxxA00A00
(4 × 16.0 + (2 × 1.0))
EYP0009YxxxxA00A00
E94AS
E94AM
EVS93
ECS
E84AVT
EYP0016YxxxxA00A00
The EYP0009... system cable can only be connected to the motor using an enlarger.
The EYP0016... system cable can only be connected to the motor using an enlarger.
Cable properties
Mechanical/design: ^ 53 Electrical/temperature range: ^ 54 Chemical: ^ 55
Important notes
For trailing cables: ^ 27
For the dimensioning: ^ 24 et seqq.