12 Error messages
12.1 Short overview of the EtherCAT error messages
92
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12 Error messages
This chapter provides the error messages of the communication module E84AYCET EtherCAT as a
supplement to the error list in the software manual and the »Engineer« online help for the Inverter
Drives 8400.
12.1 Short overview of the EtherCAT error messages
The following table lists all EtherCAT error messages in numerical order of the error number.
Furthermore the preset error response and – if available – the parameters for setting the error
response are specified.
Tip!
When you click the cross-reference in the first column, you will see a detailed description
(causes and remedies) of this error message.
Software manual/online help for the Inverter Drive 8400
Here you can find general information on diagnostics & fault analysis and on error
messages.
Error no.
[hex]
Subject area
no.
[dec]
Error no.
[dec]
Error text Error type
(Error response)
Adjustable
in
0x01bc3100
444 12544 Lost connection to 8400 base device 1: Fault -
0x01bc5531
444 21809 Memory: No access 1: Fault -
0x01bc5532
444 21810 Memory: Read error 1: Fault -
0x01bc5533
444 21811 Memory: Write error 1: Fault -
0x01bc6010
444 24592 Restart by watchdog reset 1: Fault -
0x01bc6011
444 24593 Internal error 1: Fault -
0x01bc6100
444 24832 Internal error 1: Fault -
0x01bc6101
444 24833 Internal error 1: Fault -
0x01bc641f
444 25631 Invalid parameter record 1: Fault -
0x01bc6420
444 25632 Error: Lenze setting loaded 1: Fault -
0x01bc6430
444 25648 Invalid module configuration 1: Fault -
0x01bc8131
444 33073 "Operational" status quit 0: No response C13880/1
0x01bc8700 444 34560 Sync telegram failure 0: No response C13880/2
Comentarios a estos manuales