4Technical data
4.2 Protective insulation
16
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2 Protective insulation
Danger!
Dangerous voltage
If Inverter Drives 8400 are used on a phase earthed mains with a rated mains voltage
400 V, external measures need to be implemented in order to provide reliable
protection against accidental contact.
Possible consequences:
Death or severe injury
Protective measures:
If protection against accidental contact is required for the control terminals of the
inverter and the connections of the plugged device modules, ...
a double isolating distance must be available.
the components to be connected must be provided with a second isolating distance.
Note!
The protective insulation provided in Inverter Drives 8400 is realised in accordance with
EN 61800-5-1.