Lenze DDS Target 9300 Servo PLC V8.x Manual de usuario Pagina 56

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 169
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 55
2.11 FCODE_FreeCode (node number 141)
9300 Servo PLC
System blocks
2−50
L
9300 Servo PLC EN 5.1
System variables
Variable Data type Signal type Address Display
code
Display
format
Note
FCODE_nC17_a
Integer Analog
%IW141.0
Default = 50 rpm
FCODE_nC26_1_a
%IW141.2 Default = 0.00 %
FCODE_nC26_2_a
%IW141.3 Default = 0.00 %
FCODE_nC27_1_a
%IW141.4 Default = 100.00 %
FCODE_nC27_2_a
%IW141.5 Default = 100.00 %
FCODE_nC32_a
%IW141.6 Default = 1
FCODE_nC37_a
%IW141.7 Default = 0 rpm
FCODE_nC108_1_a
%IW141.8 Default = 100.00 %
FCODE_nC108_2_a
%IW141.9 Default = 100.00 %
FCODE_nC109_1_a
%IW141.10 Default = 0.00 %
FCODE_nC109_2_a
%IW141.11 Default = 0.00 %
FCODE_nC141_a
%IW141.12 Default = 0.00 %
FCODE_bC250_b Bool Binary %IX141.13.0 Default = 0
FCODE_bC471Bit0_b
...
FCODE_bC471Bit15_b
Bool Binary
%IX141.14.0
...
%IX141.14.15
Default = 0
FCODE_bC471Bit16_b
...
FCODE_bC471Bit31_b
%IX141.15.0
...
%IX141.15.15
FCODE_nC472_1_a
...
FCODE_nC472_20_a
Integer Analog
%IW141.16
...
%IW141.35
Default = 0.00 %
C0472/3 = 100.00 %
FCODE_nC473_1_a
...
FCODE_nC473_10_a
Integer Analog
%IW141.36
...
%IW141.45
Default = 0
C0473/1, 2 = 1
FCODE_dnC474_1_p
...
FCODE_dnC474_5_p
Double integer Position
%ID141.23
...
%ID141.27
Default = 0
FCODE_nC475_1_v
Integer Velocity
%IW141.56
Default = 0
FCODE_nC475_2_v
%IW141.57
FCODE_bC135Bit0_b
...
FCODE_bC135Bit15_b
Bool Binary
%IX141.58.0
...
%IX141.58.15
Default = 0
Vista de pagina 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 168 169