3.6 Code table
9300 Servo PLC
Appendix
3−130
L
9300 Servo PLC EN 5.1
Code InformationPossible settingsLCDCode Information
SelectionLenze
LCD
C0150 Status word
g
Status word DCTRL_wStat
FCODE_bC150Bit0_b ... FCODE_bC150Bit15_b
0 {1} 65535
Decimal value is bit−coded:
Bit 00 Freely configurable 0
Bit 01 Pulse inhibit (IMP)
Bit 02 Freely configurable 2
Bit 03 Freely configurable 3
Bit 04 Freely configurable 4
Bit 05 Freely configurable 5
Bit 06 n = 0
Bit 07 Controller inhibit (CINH)
Bit 08 Status
Bit 09 Status
Bit 10 Status
Bit 11 Status
Bit 12 Warning
Bit 13 Message
Bit 14 Freely configurable 14
Bit 15 Freely configurable 15
DCTRL_bStateB0_b
DCTRL_bStateB2_b
DCTRL_bStateB3_b
DCTRL_bStateB4_b
DCTRL_bStateB5_b
DCTRL_bStateB14_b
DCTRL_bStateB15_b
[C0151] CAN/AIF FDO
g
Free digital CAN/AIF outputs
0 {hex} FFFF
Hexadecimal value is bit−coded:
1 Bit 00 CAN1_bFDO0_b
... ...
Bit 15 CAN1_bFDO31_b
CAN1_OUT
2 Bit 00 CAN2_bFDO0_b
... ...
Bit 15 CAN2_bFDO31_b
CAN1_OUT
3 Bit 00 CAN3_bFDO0_b
... ...
Bit 15 CAN3_bFDO31_b
CAN1_OUT
4 Bit 00 AIF1_bFDO0_b
... ...
Bit 15 AIF3_bFDO31_b
AIF1_OUT
C0155 Status word 2 (extended status word)
0 {1} 65535
Decimal value is bit−coded:
Bit 00 Fail
Bit 01 Mmax
Bit 02 Imax
Bit 03 IMP
Bit 04 RDY
Bit 05 RSP
Bit 06 TRIP
Bit 07 Init
Bit 08 CW/CCW
Bit 09 Not assigned
... ...
Bit 15 Not assigned
Vista de pagina 135