Lenze DDS Target 9300 Servo PLC V8.x Manual de usuario Pagina 125

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 169
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 124
9300 Servo PLC
Appendix
3.6 Code table
3−119
L
9300 Servo PLC EN 5.1
3.6 Code table
How to read the code table:
Column Abbreviation Meaning
Code C0168
1
2
8
Code C0168
Subcode 1 of code C0168
Subcode 2 of code C0168
Subcode 8 of code C0168
[C0156] Parameter value of code can only be changed when controller is inhibited.
LCD Keypad LCD
Lenze
Lenze setting of the code
g Display code (can only be displayed)
The "info" column contains more information.
Selection 1 {1 %} 99 Minimum value {smallest step/unit} maximum value
Informati
on
Additional information on code
Code LCD
Possible settings
Information
Lenze Selection
[C0002] Par load 0 Load parameter set
Only possible when PLC has been stopped.
Parameter set 1 is automatically loaded after
power−on.
0 Load Lenze setting into RAM
1 Load parameter set 1 into RAM
2 Lenze setting and codes−
Load initialisation values into RAM
C0003 Par save 0 Save parameter set
Also possible when PLC is in operation.
0 Saving completed
1 Non−volatile saving of parameter set 1
C0004 Op display 56 Keypad operating display
Keypad will indicate selected code in the operating
level if no other status indications of C0183 are active.
All available codes
[C0006] Op mode Operating mode of the motor control
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
Change of C0006 sets C0086 = 0.
ESC (Extended Speed Control):
Speed control with increased speed control steadiness
for operation with incremental encoder only (not
resolver!).
2 Servo async Y Servo control for asynchronous motors in star connection
3 Servo PM−SM Y Servo control for synchronous motors in star connection
22 Servo async Servo control for asynchronous motors in delta connection
31 ASM Y − ESC Servo control for asynchronous motors in star connection,
ESC
32 PM−SM Y − ESC Servo control for synchronous motors in star connection,
ESC
33 ASM − ESC Servo control for asynchronous motors in delta connection,
ESC
C0009 LECOM address 1 LECOM controller address
(bus device number for operation via interface)
10, 20, ..., 90 reserved for broadcast to device groups
for RS232, RS485, fibre optics.
1 {1} 99
Vista de pagina 124