Lenze DDS System bus CAN for PLC Manual de usuario Pagina 94

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 93
7.2 CAN1_IO (node number: 31) − Drive PLC
System bus (CAN) for Lenze PLC devices
CAN system blocks
7−6
L
PLC−Systembus EN 2.0
7.2 CAN1_IO (node number: 31) − Drive PLC
This SB serves to transmit cyclic process data via the system bus.
· For the transmission a sync telegram is required, which has to be generated by a different
node.
(^ 2−9)
CAN1_nInW0_a
CAN1_nInW1_a
CAN1_bInB _b0...15
CAN1_bInB _b16...31
System bus interface
Byte
7
8
5
6
3
4
1
2
Byte
7
8
5
6
3
4
1
2
CAN1_nOutW0_a
CAN1_nOutW1_a
CAN1_nOutW2_a
CAN1_bFDO _b16...31
CAN1_dnOutD1_p
CAN1_IO
DINT
WORD
WORD
WORD
16 x BOOL
DINT
Output user data
(8 bytes)
Input user data
(8 bytes)
L
H
L
H
CAN1_bFDO _b0...15
16 x BOOL
CAN1_nOutW3_a
WORD
CAN1_nInW2_a
CAN1_nInW3_a
CAN1_dnInD1_p
C0868/1
C0869/1
C0868/2
C0868/3
C0867/1
CAN1_bFDO _b32...47
16 x BOOL
CAN1_bFDO _b48...63
16 x BOOL
WORD
WORD
16 x BOOL
16 x BOOL
WORD
C0866/1
C0866/2
C0866/3
16 x BOOL
16 x BOOL
WORD
C0136/2
CAN1_bInB _b32...47
CAN1_bInB _b48...63
Fig. 7−2 CAN1_IO system block
Vista de pagina 93
1 2 ... 89 90 91 92 93 94 95 96 97 98 99 ... 177 178

Comentarios a estos manuales

Sin comentarios