7.1 CAN1_IO (node number: 31) − 9300 Servo PLC
System bus (CAN) for Lenze PLC devices
CAN system blocks
7−4
L
PLC−Systembus EN 2.0
Variables for received user data
User data Assigned variables
Byte Bit Variable (1 bit) Variable (16 bit) Variable (32 bit)
1
0 CAN1_bInB0_b
CAN1_wDctrlCtrl
1 CAN1_bInB1_b
2 CAN1_bInB2_b
3 CAN1_bCtrlQuickstop_b
4 CAN1_bInB4_b
5 CAN1_bInB5_b
6 CAN1_bInB6_b
7 CAN1_bInB7_b
2
0 CAN1_bCtrlDisable_b
1 CAN1_bCtrlCInhibit_b
2 CAN1_bCtrlTripSet_b
3 CAN1_bCtrlTripReset_b
4 CAN1_bInB12_b
5 CAN1_bInB13_b
6 CAN1_bInB14_b
7 CAN1_bInB15_b
3 0...7
CAN1_nInW1_a
4 0...7
5 0
...
7
CAN1_bInB0_b
...
CAN1_bInB7_b
CAN1_nInW2_a
CAN1_dnInD1_p
6 0
...
7
CAN1_bInB8_b
...
CAN1_bInB15_b
7 0
...
7
CAN1_bInB16_b
...
CAN1_bInB23_b
CAN1_nInW3_a
8 0
...
7
CAN1_bInB24_b
...
CAN1_bInB31_b