Lenze E94AYCPM Manual de usuario Pagina 111

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 125
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 110
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17 111
14 Parameter reference
14.4 Table of attributes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.4 Table of attributes
The table of attributes contains information required for communication with the controller via
parameters.
How to read the table of attributes:
Column Meaning Entry
Code Parameter designation Cxxxxx
Name Parameter short text (display text) Text
Index dec Index by which the parameter is addressed.
The subindex for array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number Is only required for access via a bus
system.
hex 5FFF
h
- Lenze code number
Data DS Data structure E Single variable
(only one parameter element)
A Array variable
(several parameter elements)
DA Number of array elements (subcodes) Number
DT Data type BITFIELD_8 1 byte, bit-coded
BITFIELD_16 2 bytes, bit-coded
BITFIELD_32 4 bytes, bit-coded
INTEGER_8 1 byte with sign
INTEGER_16 2 bytes with sign
INTEGER_32 4 bytes with sign
UNSIGNED_8 1 byte without sign
UNSIGNED_16 2 bytes without sign
UNSIGNED_32 4 bytes, without sign
VISIBLE_STRING ASCII string
OCTET_STRING
Factor Factor for data transmission via a bus system,
depending on the number of decimal positions
Factor 1 no decimal positions
10 1 decimal position
100 2 decimal positions
1000 3 decimal positions
Access R Read access ; Reading permitted
W Write access ; Writing permitted
CINH Controller inhibit required ; Writing is only possible if controller inhibit is set
Vista de pagina 110