EDS84DMOTPNET EN 2.0 - 11/2011 L 77
Communication manual 8400 motec PROFINET
Parameter reference
Parameters relevant for PROFINET communication
C13851
C13860
Parameter | Name:
C13851 | All words from master
Data type: UNSIGNED_16
Index: 10724
d
= 29E4
h
Display of the process data words which are transmitted from the IO controller to the controller.
In the subcodes 1 to 8, all process data words from the I/O controller are displayed. However, only the configured
process data words are valid.
Display area (min. value | unit | max. value)
0 65535
Subcodes Info
C13851/1
...
C13851/8
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13860 | Settings
Data type: UNSIGNED_8
Index: 10715
d
= 29DB
h
Display area (min. value | unit | max. value)
0 255
Subcodes Info
C13860/1 Reserved
C13860/2 Number of process data words
C13860/3 Reserved
C13860/4 Reserved
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT