9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Parameterisable function blocks
72 L EDS94TA10030xxxx EN 1.2 - 11/2009
5.16.5 FollowError_Hysteresis
5.16.6 FollowError_Limit
5.16.7 HomingSetPosition
Is an instance of Function
L_SdSetPosition Conversion of the following error hysteresis selected in the real units of the machine
via C03916 into a position in [increments].
Following error monitoring
( 53)
Parameter Possible settings Information
C03916 -214000.0000 unit 214000.0000 Position value
• Initialisation: 0.5000 units
C03917 Character string Position unit
•Read only
C03918 -2147483647 2147483647 State
•Read only
Is an instance of Function
L_SdSetPosition Conversion of the following error limit selected in the real units of the machine via
C03911 into a position in [increments].
Following error monitoring
( 53)
Parameter Possible settings Information
C03911 -214000.0000 unit 214000.0000 Position value
• Initialisation: 1.0000 units
C03912 Character string Position unit
•Read only
C03913 -2147483647 2147483647 State
•Read only
Is an instance of Function
L_SdSetPosition Conversion of the home position selected in the real units of the machine via C03012
into a position in [increments].
"Homing" mode
( 49)
Parameter Possible settings Information
C03012 -214000.0000 unit 214000.0000 Position value
• Initialisation: 100.0000 units
C03013 Character string Position unit
•Read only
C03014 -2147483647 2147483647 State
•Read only