EDS94TA10030xxxx EN 1.2 - 11/2009 L 41
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Selection of master value source and output
5.3 Selection of master value source and output
[5-3] Signal flow for selecting the master value source and the master values to be output
Master value source
The master values can be either selected by a "Virtual master", via a bus system or the
digital frequency extension module.
Transmission of the master angle ( 12)
They can be selected on the Application parameters tab via the Master value source list
field or via C03052.
Master value output
The master value to be output ( ... ) is selected individually for the three possible
communication channels:
List field Master value output DF module (C03197):
Selection of the master value output for the digital frequency module.
List field Master value output MotionBus (C03054/1):
Selection of the master value output for horizontal communication.
List field Master value output LPort32Out1 (C03054/2):
Selection of the master value output for vertical communication.
Master value with stretch factor with clutch with trimming Actual value
v
t
Dv
3
M
024
j
v
t
Virtual master
LPortAxisIn1 LPortAxisOut1
C03054/2
C03197
C03054/1
C03052
LPort32Out1