Lenze E94AxHE Technology Application Electronic gearbox Manual de usuario Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Operating mode "Electronic gearbox"
46 L EDS94TA10030xxxx EN 1.2 - 11/2009
5.4.2 Virtual clutch
[5-6] Function "Virtual clutch" in the signal flow (schematic diagram)
Parameter setting: Tab Application parameters dialog level Overview Electronic
gearbox Virtual clutch
Configuration: Tab FB editor FB ClutchElectricalShaft
n Master value with stretch factor
o Master value with clutch
M
v
Slave
Real master/
Virtual master
v
t
Dv
C03006 = 1

Parameter Lenze setting
Value Unit
C03673 Master value with stretch factor - unit/t
C03021 Activate clutch Deactivated
C03665/1 Clutch in ramp 1.000 s
C03665/2 Decoupling ramp 1.000 s
C03665/3 Stop ramp 1.000 s
C03668 Jerk limitation 1.000 s
C03674 Master value with clutch - unit/t
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DigIn 4 Close clutch C03058/13
FALSE Clutch - positive opening operation C03058/14
Vista de pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 79 80

Comentarios a estos manuales

Sin comentarios