Lenze c300 Manual de usuario Pagina 94

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 195
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 93
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17 94
11 Remote maintenance and diagnostics
11.5 Activate Windows® CE interface
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.5.1 Remote Display: Remote control of Controller via Internet or LAN
Remote Display Control for Windows® CE (cerhost/cerdisp)
The Engineering PC requires the Remote Display Control software (cerhost.exe) which can be
downloaded from the AKB on the Lenze homepage. It is also provided on the CD that is delivered
along with the devices.
How to establish a remote display connection to the controller:
1. Find out the IP address of the Engineering PC (e.g. by executing the IPConfig command),
2. Start Remote Display Control (cerhost.exe) on the Engineering PC,
3. Start cerdisp.exe on the controller with the (previously identified) IP address of the
Engineering PC : cerdisp <IP address>
[11-2] Remote access to a controller via Remote Display Control
Vista de pagina 93