5 Commissioning the controller
5.4 Configuring the controller
33
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.4 Configuring the controller
This chapter provides information on how to configure the Controller during initial commissioning.
The IP address setting is preserved after a restart of the system.
5.4.1 Establishing an automatic dial-up connection
Further information on how to establish an automatic dial-up connection, remote maintenance and
diagnostics options can be found under:
Remote maintenance and diagnostics
( 79)
In order to carry out a remote maintenance on the controller different mechanisms are provided:
Diagnostics via Telnet
( 82)
Data transfer via FTP ( 85)
Activate Windows® CE interface ( 92)
Diagnostics with the logbook ( 89)
5.4.2 Entering the IP address of the controller
The controller has the following network settings by default:
During initial commissioning of the Controller, the desired IP address has to be entered.
Optionally, the network settings can be selected via a file:
Specifying the IP address of the controller via file (optional)
( 36)
Note!
Controller c300/p300:
• These devices come with a deactivated Telnet and FTP in the Lenze standard setting.
• The functions can be activated via the »WebConfig«. The activation of the functions
can influence the real-time behaviour.
• After a restart of the Controller, the functions are deactivated again.
Address Lenze setting
IP address 192.168.5.99
Subnetwork 255.255.255.0
Default gateway 192.168.5.1