PM94H201B_13xxxxxx_EN L 55
Programming
2.12 System Status Register (DSTATUS register)
System Status Register, (DSTATUS), is a Read Only register. Its bits indicate the various states of the PositionServo’s
subsystems. Some of the bits are available as System Flag Variables and previously summarized in Table 12.
Table 16: DSTATUS Register
Bit in register Description
0 Set when drive enabled
1 Set if DSP subsystem at any fault
2 Set if drive has a valid program
3 Set if byte-code or system or DSP at any fault
4 Set if drive has a valid source code
5 Set if motion completed and target position is within specified limits
6 Set when scope is triggered and data collected
7 Set if motion stack is full
8 Set if motion stack is empty
9 Set if byte-code halted
10 Set if byte-code is running
11 Set if byte-code is set to run in step mode
12 Set if byte-code has reached the end of program
13 Set if current limit is reached
14 Set if byte-code at fault
15 Set if no valid motor selected
16 Set if byte-code at arithmetic fault
17 Set if byte-code at user fault
18 Set if DSP initialization completed
19 Set if registration has been triggered
20 Set if registration variable was updated from DSP after last trigger
21 Set if motion module at fault
22 Set if motion suspended
23 Set if program requested to suspend motion
24 Set if system waits completion of motion
25 Set if motion command completed and motion Queue is empty
26 Set if byte-code task requested reset
27 If set interface control is disabled. This flag is set/clear by ICONTROL ON/OFF statement.
28 Set if positive limit switch active
29 Set if negative limit switch active
30
Events disabled. All events disabled when this flag is set. After executing EVENTS ON all events
previously enabled by EVENT EventName ON statements become enabled again
PositionServo variable #83 provides Extended Status Bits, the encoding of which is listed in Table 17.