3 Product description
3.3 Product features
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.3 Product features
• Interface module for the INTERBUS communication system to be connected to the expansion
slots of the Servo Drives 9400
• The communication module can either be supplied internally by the standard device or
externally by a separate voltage source.
• Slave functionality
• DIP switch settings:
• Number of process data words and parameter data words
• Baud rate (500 kbps or 2 Mbps)
• Bus coupling via remote bus according to the RS485 standard
• Up to 10 process data words (20 bytes) can be used.
• 0, 1, 2 order 4 parameter data words can be used.
• The parameter data is transmitted in accordance with the Peripherials Communication Protocol
(PCP).
• Access to all Lenze parameters
• Support of the PMS services:
•Initiate
•Abort
• Reject
•Read
•Write
•Get-OD
•Identify
• Status