EDS84DPNET EN 4.0 - 11/2010 L 65
Communication manual 8400 protec PROFINET
Error messages
Possible causes and remedies
PROFINET: IP address error [0x01bc6533]
PROFINET: Stack init error [0x01bc6534]
PROFINET: Safety communication timeout [0x01bc6610]
PROFINET: Safety parameter timeout [0x01bc6611]
PROFINET: Safety init error [0x01bc6612]
Response (Lenze setting in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
An invalid IP address has been assigned by the IO
controller via PROFINET or has been set in code C13000
.
Make sure that the IO controller has assigned a valid
IP address via PROFINET.
Set a valid IP address.
Setting the IP configuration
( 27)
Response (Lenze setting in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The stack cannot be initialised with the parameters
selected by the user. This may be due to a station name
which does not comply with the PROFINET specification.
Check and, if necessary, adapt PROFINET parameters:
Setting the IP configuration
( 27)
Setting the station name
( 25)
Response (Lenze setting in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning Information
Cause Remedy
This is an error message occurring during every safe
parameter download.
Reset error.
Response (Lenze setting in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning Information
Cause Remedy
The SO20/SO30 safety option does not respond to a
PROFISafe parameterisation telegram (PRM data) within
a given time interval (200 ms).
Activate the SO20/SO30 safety option.
Response (Lenze setting in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning Information
Cause Remedy
Communication with the SO20/SO30 safety option
could not be initialised correctly.
The IO controller has defined a safety application,
however, no connection to the safety option was
recognised internally.
Activate the SO20/SO30 safety option.