EDS84DPNET EN 4.0 - 11/2010 L 47
Communication manual 8400 protec PROFINET
Parameter data transfer
Writing parameters to the controller
8.3.1 Response after a correct write request
Response header
8.3.2 Response after a write error
Byte 1 Byte 2 Byte 3 Byte 4
Request reference
(mirrored)
Response identifier Axis
(mirrored)
Number of indices
Field Data type Values
Request reference U8 Mirrored value of parameter request
Response identifier U8 0x01: Parameter written
Axis U8 0x00 or 0x01
Number of indices U8 0x"n" (n = number of parameters requested)
Note!
For a multi-parameter request, correct and faulty messages, if any, are combined
in one telegram. The individual messages have the following data contents:
Correct message
Format: 0x40
Number of values: 0x00
Faulty message
Format: 0x44
Number of values: 0x01 or 0x02
Error code without additional information (number of values = 0x01) or
Error code with additional information (number of values = 0x02)
Faulty access to a parameter "n" will be reported in the response message of a
multi-parameter request at position n.