Application examples
4.3 Filling process
4−9
l
EDSVS9332K−EXT EN 4.0
+UG -UG
X4
HI
X5
93XX
X10
-
DC 24V
M
RS
39
+
±10V
1
X6
2
GND
LO
59
39
U
L1
1
0
L2 L3
VW X7
A1A2 A3 A4
28 E1E2 E3 E4 E5
9300kur048
Fig. 4−8 Wiring principle for the controller
Controller for pump drive
Speed setpoint
RS Resolver
Features
l Product−specific filling with minimum bubble generation
l Virtual master value
l Product changes possible at every clock pulse
l Option: Switching point for handshake with conveyor belt
Digital signals (C0005 = 13000)
Terminal Function
X5/28 Controller enable
X5/E1 Selection of event profile (C1420)
X5/E2 Profile selection (see table for terminal layout)
X5/E3 Profile selection (see table for terminal layout)
X5/E4 Profile selection (see table for terminal layout)
X5/E5 Error reset (TRIP reset) / profile acceptance
X5/A1 Error (TRIP)
X5/A2 Following error limit reached
X5/A3 Ready for operation (RDY)
X5/A4 Following error warning limit reached
Analog signals (C0005 = 13000)
Terminal Function
Analog input 1: X6/1, X6/2 Setpoint of virtual master
Analog input 2: X6/3, X6/4 Not assigned
Analog output 1: X6/62 Actual speed
Analog output 2: X6/63 Actual torque
Digital frequency output X10: virtual master value