Function library
Function blocks
3.2.103 Stretching, compression, offset in Y direction (YSET1)
3−332
l
EDSVS9332K−EXT EN 4.0
3.2.103.3 Reset of the offset
The function "OFFS−RESET mode" has the following effect on the output signal YSET1−OUT:
l C1364/1 = 0: (Lenze setting). Output YSET1−OUT is not affected by
signal at input YSET1−RESET,
signal at YSET1−OFFS, as long as YSET1−RESET = HIGH.
l C1364/1 = 1: When YSET1−RESET = HIGH, the offset is subtracted from the output signal at
YSET1−OUT.
3.2.103.4 Stretching/compression of the offset
With C1351 the offset is automatically adapted to the profile zero according to the extension factor.
l C1351 = 0: no stretching/compression of the offset (Lenze setting)
l C1351 = 1: stretching/compression of the offset
3.2.103.5 Direction reversal
There are two possibilities to reverse the direction of rotation:
1. Via C1350
CW rotation: C1350 = 0
CCW rotation: C1350 = 1
2. Application of a stretching/compression factor
YSET1−FACT = 100 % (see also table in chapter 3.2.103.1)