Industrial PC | Parameter setting & configuration
Commissioning
Control elements
28 L 2.5 EN - 01/2012
How to start the function key assignment in the »Engineer«:
1. Highlight the corresponding Industrial PC in the project view.
2. Establish the online connection to the Industrial PC selected.
Observe the chapter "Establishing the online connection to an Industrial PC" in
the »Engineer« documentation.
3. Click the Settings tab.
For every function key a selection list with different functions is available:
–The Start program option enables linking a function key to the start of an
application,
Touch keyboard assigns the function key to the on-screen keyboard,
Right mouse-click assigns the function key with the right mouse-click,
Run AP script starts an automation panel script,
Start control panel starts the Windows® CE control panel.
Alternatively the function key assignments can also be configured via codes C432 to
C439.