Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
134 L 2.5 EN - 01/2012
C0057
C0058
C0064
C0070
C0071
C0072
Parameter | Name:
C0057 | Logbook: Index of last entry
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Number of the last entry in the logbook
Display range
(min. value | unit | max. value)
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0058 | Logbook: Time of last entry
Data type: DATE
Index: 24517
d
= 5FC5
h
Time of the last entry in the logbook
Display range
(min. value | unit | max. value)
(UTC)
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0064 | Logbook: Time of last error entry
Data type: DATE
Index: 24511
d
= 5FBF
h
Entry of the last time error in the logbook
Display range
(min. value | unit | max. value)
(UTC)
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0070 | Ratio: Data/program memory
Data type: UNSIGNED_32
Index: 24505
d
= 5FB9
h
A part of the available memory is provided to the current programs as main memory.
The other part is available as object store for saving files in the RAM.
The percentage value indicated shows the ratio between object store (MemoryVirtualFilesAll) and total memory.
Setting range
(min. value | unit | max. value) Lenze setting
0 % 100 50 %
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0071 | Allocated program memory
Data type: UNSIGNED_32
Index: 24504
d
= 5FB8
h
Size of the reserved program memory
Display range
(min. value | unit | max. value)
0 Bytes 4294967295
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0072 | Used program memory
Data type: UNSIGNED_32
Index: 24503
d
= 5FB7
h
Size of the occupied program memory
Display range
(min. value | unit | max. value)
0 Bytes 4294967295
; Read access Write access CINH PLC STOP No transfer