Industrial PC | Parameter setting & configuration
Parameter reference
Panel
156 L 2.5 EN - 01/2012
C0423
C0424
C0431
C0432
C0433
Parameter | Name:
C0423 | Brightness: Upper limit
Data type: UNSIGNED_8
Index: 24152
d
= 5E58
h
Enter the maximum brightness value of the display. The numerical values are between the
maximum = 0 and the
minimum = 63
Setting range
(min. value | unit | max. value) Lenze setting
0630
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0424 | Auto dimming time
Data type: UNSIGNED_8
Index: 24151
d
= 5E57
h
Enter the time after which the display is dimmed automatically. The numerical values are between the
maximum = 0 and the
minimum = 255
Setting range
(min. value | unit | max. value) Lenze setting
0 s 255 0 s
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0431 | Key status
Data type: UNSIGNED_32
Index: 24144
d
= 5E50
h
Key status as a numerical value
Display range
(min. value | unit | max. value)
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0432 | Key F1: Function
Data type: UNSIGNED_32
Index: 24143
d
= 5E4F
h
Assignment of F1 key function. The different functions are assigned via a selection list.
Selection list
(Lenze setting printed in bold) Information
0None
1 Start program
2 Touch keyboard
3 Right mouseclick
4Run AP script
5Start Control Panel
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0433 | Key F1: Parameter
Data type: VISIBLE_STRING
Index: 24142
d
= 5E4E
h
Name of the script or program to be executed
; Read access ; Write access CINH PLC STOP No transfer