Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
148 L 2.5 EN - 01/2012
C0168
C0169
C0170
C0171
C0172
C0173
Parameter | Name:
C0168 | FTP: Home user 10
Data type: VISIBLE_STRING
Index: 24407
d
= 5F57
h
Home directory of the user
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0169 | WinCE-User: User 10 with telnet permissions
Data type: UNSIGNED_8
Index: 24406
d
= 5F56
h
User may use telnet
Setting range
(min. value | unit | max. value) Lenze setting
010
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0170 | WinCE-User: User 10 with RAS permissions
Data type: UNSIGNED_8
Index: 24405
d
= 5F55
h
User may use RAS
Setting range
(min. value | unit | max. value) Lenze setting
010
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0171 | FTP: Use authentication
Data type: UNSIGNED_32
Index: 24404
d
= 5F54
h
The FTP user has to identify himself/herself with name and password to establish a connection.
Entering "1" activates the log-in procedure
Entering "0" deactivates the log-in procedure
Setting range
(min. value | unit | max. value) Lenze setting
011
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0172 | FTP: Allow anonymous
Data type: UNSIGNED_32
Index: 24403
d
= 5F53
h
An unregistered users is allowed to log in. The user name is "anonymous"
Entering "1" activates the log-in procedure
Entering "0" deactivates the log-in procedure
Setting range
(min. value | unit | max. value) Lenze setting
010
; Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0173 | FTP: Allow anonymous upload
Data type: UNSIGNED_32
Index: 24402
d
= 5F52
h
An anonymous user is allowed to upload data to the IPC with the following code setting:
FtpAllowAnonymousUpload = true and
FtpAllowAnonymous = true.
Setting range
(min. value | unit | max. value) Lenze setting
011
; Read access ; Write access CINH PLC STOP No transfer