L-force Controls | I/O System 1000
Parameter setting
Electronic modules - counters
52 L 2.0 EN - 11/2010
6.6.5 Counting only once: Main counting direction - counting up
Function:
The counter starts counting up from the start value.
If the counter reaches the final value -1 in the positive direction, it jumps to the start
value with the next count pulse and the counter will stop automatically.
After a restart, the counter starts counting from the start value.
The counter is able to continue counting below the lower counting limit value.
[6.4] Example of "Counting only once" with main counting direction - counting up
Limits Counting range
Final value -2 147 483 646 (-2
31
+1) … +2 147 483 646 (-2
31
-1)
Lower counting limit +2 147 483 648 (-2
31
)