Codes
Monitoring codes
10
l
122
EDSMF2133IB EN 5.0
10.2 Monitoring codes
C0126:
Behaviour with communication error (extract)
Code Subcode Index
Possible settings
Data type
Lenze Selection
C0126 24449
d
=
5F81
h
See documentation for the controller. FIX32
Monitoring the internal communication between communication module and controller.
C1882:
Process data
monitoring response
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1882 22693
d
=
58A5
h
0
0 [1] 3
U32
Value = [selection] x 10000
Selection Response
0 No response
1 Fault (TRIP)
2 Controller inhibit (CINH))
3 Quick stop (QSP)
The Lenze code is used to determine the controller reaction when the process data
monitoring time has expired.
This function can be used for:
ƒ DRIVECOM control
ƒ PROFIdrive control
ƒ device control
I Tip!
ƒ Code C1882 performs the same function as the index6004
hex
.
ƒ Observe the notes with regard to the interruption of the PROFIBUS
communication ( 118)
Vista de pagina 121