Electrical installation
Wiring of the feedback system
Digital frequency input/output (encoder simulation)
5
129
EDKCSEX064 DE/EN/FR 6.0
5.5.3 Digital frequency input/output (encoder simulation)
The digital frequency coupling of ECSxS/P/A axis modules basically is effected
as a master−slave connection via the interface X8. This interface can either be
used as a digital frequency input or as a digital frequency output (e. g. for
encoder simulation) (configuration via C0491).
Features
X8 as digital frequency input X8 as digital frequency output
l Input frequency: 0 ... 200 kHz
l Current consumption: max. 6 mA per
channel
l Two−track with inverse 5 V signals and zero
track
l Possible input signals:
incremental encoder with two 5 V
complementary signals (TTL encoders)
offset by 90°
l The function of the inputs signals can be set
via C0427.
l Output frequency: 0 ... 200 kHz
l Permissible current loading: max. 20 mA per
channel
l Two−track with inverse 5 V signals (RS422)
l The function of the output signals can be set
via C0540.