EDS84AYCIB EN 4.0 - 11/2010 L 51
E84AYCIB communication manual (INTERBUS)
Parameter data transfer
Supported PMS services
9.3.6 Identify
The "Identify" PMS service provides information on how to identify the controller.
The controller with the plugged-on communication module provides the following
parameters for this:
Example: Visible string "device type" (15 characters)
Structure of the visible string "device version" (15 characters)
Parameter Type Description
Device manufacturer Visible string Company name "Lenze"
Device type Visible-string (15 characters) Device name for the controller and the
communication module
Device version Visible-string (15 characters) Firmware version of the controller and the
communication module
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
E 8 4 A F G H C A F Y I B
Character Description
1 ... 3 Product range of the controller and the communication module (E84 = 8400 series)
4Blank
5 ... 6 A: Version of the controller
F: Firmware of the controller
7 ... 9 G: Device / controller
SC: StateLine C
HC: HighLine C
10 Blank
11 ... 12 A: Version of the communication module
F: Firmware of the communication module
13 ... 15 Y: Communication module
IB: INTERBUS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0 4 . 0 0 0 1 . 0 0
Character Description
1 ... 5 Firmware version of the controller (from C00099/0, e.g. "04.00.xx.yy", without internal revision
status ["xx"] and build status ["yy"])
6Blank
7 ... 11 Firmware version of the communication module (from C13902
, e.g. "01.00.xx.yy", without internal
revision status ["xx"] and build status ["yy"])
12 ... 15 Blank