Lenze E84AYCIB Manual de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 75
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
EDS84AYCIB EN 4.0 - 11/2010 L 21
E84AYCIB communication manual (INTERBUS)
Technical data
Protocol data
4.3 Protocol data
4.4 Communication time
The communication time is the time between the start of a request and the arrival of the
corresponding response.
The communication times in the INTERBUS network depend on the...
Processing time in the controller;
Telegram runtime (baud rate / telegram length).
Processing time in the controller
The parameter data and process data are independent of each other.
Field Values
Process data words 0 ... 10 words (16 bits/word)
Supported PMS services Initiate
•Abort
Reject
•Read
•Write
•Get-OD
•Identify
Status
Data Processing time
Process data Approx. 2ms + 1ms tolerance + runtime of the technology application used
Parameter data Approx. 30 ms + 20 ms tolerance (typical)
Some codes may require a longer processing time (see software manual/
»Engineer« online help for Inverter Drives 8400).
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 74 75

Comentarios a estos manuales

Sin comentarios