Lenze PLC Designer PLC-Designer (R2-x) SoftMotion Manual de usuario Pagina 237

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 290
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 236
DMS 5.2 EN 03/2011 TD17 L 237
L-force | PLC Designer - SoftMotion
The SM_Trafo.lib library
Transformation function blocks
dRotationOffset: LREAL
Direction in which axis A is facing when viewed from the origin (0/0), in degrees
(mathematical sense)
dOffsetA, dOffsetB, dOffsetC: LREAL
Offset of the individual axes
Outputs (VAR_OUT)
bError BOOL
TRUE: Impermissible values
dx, dy, dz: LREAL
x, y, z position of the centre of the inner ring in geo coordinates
dnx, dny: LREAL
Standardised position of the manipulator (for visualisation)
dRatioInnerOuter: LREAL
Ratio of the radius of the inner ring to that of the outer ring (for visualisation)
adnxi, adnyi, adnxo, adnyo: ARRAY[0...5] OF LREAL
Standardised start and end position of the struts (for visualisation)
Vista de pagina 236
1 2 ... 232 233 234 235 236 237 238 239 240 241 242 ... 289 290

Comentarios a estos manuales

Sin comentarios