Lenze PLC Designer PLC-Designer (R2-x) SoftMotion Manual de usuario Pagina 121

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 290
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 120
DMS 5.2 EN 03/2011 TD17 L 121
L-force | PLC Designer - SoftMotion
The SM_PLCopen.lib library
POUs for the motion control of individual axes
6.2.14 SMC_MoveContinuousAbsolute
This POU moves the axis to a fixed position according to the specified values for speed,
acceleration, and deceleration. In contrast to MC_MoveAbsolute, the user can additionally
define a final speed that the axis has at this position, which the POU displays by the output
InEndVelocity. If the POU is not interrupted by another POU, it keeps on moving the axis
continuously (axis status = move_continuous) with the final speed defined.
By corresponding specifications (path required to bring the axis to the final speed
< distance between the position at the start and target position) it can happen that the
axis at first carries out a movement in the opposite direction.
Input/output (VAR_IN_OUT)
Axis : AXIS_REF
The structure that is filled with axis data in the Drive Interface (SM_DriveBasic.lib) is shown
here.
Vista de pagina 120
1 2 ... 116 117 118 119 120 121 122 123 124 125 126 ... 289 290

Comentarios a estos manuales

Sin comentarios