L-force | PLC Designer - SoftMotion
The SM_CNC.lib library
SMC_GCodeViewer
Outputs (VAR_OUT)
bError : BOOL
This value will be set to TRUE if an error occurs.
wErrorID: SMC_ ERROR (INT)
This Enum output possibly describes an error that has occurred. After an error the data
preparation is stopped until the POU is started again by a new bEnable.
asGCode: ARRAY[0...c_uiLines] OF STRING
Text lines containing the current segment of the G-code. The first element contains the line
which is currently traversed by the interpolator.