EDS94TA10040xxxx EN 1.1 - 10/2008 L 73
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
C03831 -2147483647 unit/t 2147483647 Speed at the input
•Read only
• Is generated from the speed
signal dnSetSpeedIn_s.
C03832 -2147483647 unit/t 2147483647 Speed at the output
•Read only
• Is generated from the speed
signal dnSpeedOut_s.
C03833 -214748.3647 unit 214748.3647 Set position at the output
• Display of output signal
dnSetPosCycle_p in real unit of the
machine.
C03834 -214748.3647 unit 214748.3647 Actual position at the output
• Display of output signal
dnActPosCycle_p in real unit of the
machine.
C03835 -214748.3647 unit 214748.3647 Following error
• Display of output signal
dnFollowErrore_p in real unit of
the machine.
C03836 -214748.3647 unit 214748.3647 Measured TP deviation
• Display of output signal
dnDifference_p in real unit of the
machine.
C03837 -214748.3647 unit 214748.3647 Measured cycle
• Display of output signal
dnTpTpDistance_p in real unit of
the machine.
C03838 -214748.3647 unit 214748.3647 TP set position at the input
•Display of the dnTpPos_p input
signal in the real unit of the
machine.
Parameter Possible settings Information
Comentarios a estos manuales