EDS94TA10040xxxx EN 1.1 - 10/2008 L 55
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
4.14.2 ClutchElectricalShaft
Is an instance of Function
L_LdClutchAxisP Time-controlled virtual clutch with position reference
Virtual clutch
(C 36)
Parameter Possible settings Information
C03665/1 0.010 s 130.000 Clutch in ramp
Acceleration ramp for
synchronising to the master shaft.
Initialisation: 1.000 s
C03665/2 0.010 s 130.000 Decoupling ramp
Deceleration ramp for stop of
master position.
Initialisation: 2.000 s
C03665/3 0.010 s 130.000 Ramp for positive opening operation
Deceleration ramp for positive
opening operation.
Initialisation: 1.000 s
C03666/1 String of digits Position unit
•Read only
C03666/2 String of digits Speed unit
•Read only
C03667 -214748.3647 unit/t 214748.3647 Reference speed
•Read only
Reference value for selecting
speeds.
C03669 -2147483647 2147483647 Status
Display of the bit-coded output
signal dnState.
C03671 -214748.3647 unit 214748.3647 Set position after decoupling
•Display of the dnOpenPosition_p
input signal in the real unit of the
machine.
C03672 -214748.3647 unit 214748.3647 Actual position of the master angle
Display of input signal
dnActPostion_p in real unit of the
machine.
C03673 -214748.3647 unit 214748.3647 Master position at the input
Display of input signal
dnSetPostion_p in real unit of the
machine.
C03674 -214748.3647 unit 214748.3647 Master position at the output
•Display of the dnPosOut_p output
signal in the real unit of the
machine.