Lenze E94AxHE Technology Application Synchronism Manual de usuario Pagina 36

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 35
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
36 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.5.3 Virtual clutch
[4-7] Function "Virtual clutch" in the signal flow (schematic diagram)
r Parameter setting: Tab Application parameters dialog level Overview Virtual clutch
r Configuration: Tab FB editor FB ClutchElectricalShaft
nMaster value with stretch factor
o Master value with clutch

M
v
Slave
Real master/
Virtual master
C03006 = 0
v
t
Dj
Dj Dj
TP TP
Parameter Lenze setting
Value Unit
C03672 Master value with stretch factor - unit
C03021 Activate clutch Deactivated
C03665/1 Clutch in ramp 1.000 s
C03665/2 Decoupling ramp 2.000 s
C03665/3 Ramp for positive opening operation 1.000 s
C03674 Master value with clutch - unit
C03679 Standstill position selection 0.0000 unit
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DIGIN 4 Close clutch C03058/13
FALSE Clutch - positive opening operation C03058/14