Lenze E94AxHE Technology Application Synchronism Manual de usuario Pagina 56

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 55
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
56 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.14.3 ClutchStopPosition
4.14.4 CompareTPDiffShaft
Is an instance of Function
L_SdSetPosition Conversion of the set position after decoupling selected in the real units of the
machine via C03679 into a position in [increments].
Virtual clutch
(C 36)
Parameter Possible settings Information
C03679 -214000.0000 unit 214000.0000 Position value
Initialisation: 0.0000 unit
C03680 String of digits Position unit
•Read only
C03681 -2147483647 2147483647 Status
•Read only
Is an instance of Function
L_TbCompare Mark synchronisation (master value):
Comparison of the determined TP difference and the TP limit parameterised in
C03651 for the status message "TP limit exceeded" via C03655.
Mark synchronisation (master value)
(C 34)
Parameter Possible settings Information
C03650 Comparison function
0 dnIn1 = dnIn2
1 dnIn1 > dnIn2 Lenze setting
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|
Vista de pagina 55