Maintenance
Maintenance intervals
Replacing the lubricant
7
18
BA 12.0030 EN 2.0
7.1.1 Replacing the lubricant
Stop!
ƒ
Gearbox should be warm.
ƒ
Secure drive system and machine from inadvertent movement and mains
connection.
1. Drain lubricant by removing the oil drain/filler plug.
2. Fill recommended lubricant in the specified amount.
3. Insert oil drain/filler plug with new seal.
4. Dispose of waste oil according to applicable regulations.
Fig. 1 Position of oil filler/drain plug
Oil filler/drain plug
Recommended lubricant
Manufacturer Mobil Optimol
Type Mobil SHC 629 Optigear Synthetic A 150