Maintenance
Maintenance intervals
7
17
BA 12.0030 EN 2.0
7 Maintenance
Gearboxes and geared motors from Lenze are filled with a drive-specific and
design-specific lubricant filling at delivery. The mounting position and design are decisive
at ordering for the required lubricant q uantity.
Note!
When changing the lubricant, Lenze recommends also changing the grease
packing of the bearings and replacing the radial shaft seal rings!
7.1 Maintenance intervals
ƒ The mechanical power transmission system is free of maintenance.
ƒ Shaft seals:
– The service life depends on the ambient conditions.
– Replace seals in case of leakage to avoid consequential damage.
ƒ Lubricating intervals:
– Gearboxes of type GPA are lubricated for life and hermetically sealed. In normal
operation, a lubricant change is not required.
– With extremely severe operation, we recommend changing the lubricant every
10,000 operating hours.
– The type of lubricant is indicated on the nameplate. Replace the lubricant only b y
thesametype.
Stop!
For drive systems: Also observe the maintenance intervals for the other drive
components!
Lubricants Changing intervals
Type Specification Ambient
temperature
Note
CLP PAO 150 Oil on synthetic basis
(polyglycol)
-20 °C...40 °C Do not mix with
mineral oils!
10,000 operating hours, no longer
than three years
(oil temperature 70...100 °C)