Installation
Electrical installation
36 L EDS84AYCEC EN 3.0 - 09/2012
Assignment of the X250 plug connector
Terminal data
Designation Description
+ U = 24 V DC (20.4 V - 0 % ... 28.8 V + 0 %)
I = 140 mA
- Reference potential for external voltage supply
Field Values
Electrical connection 2-pin plug connector with spring connection
Possible connections rigid:
0.2 ... 1.5 mm
2
(AWG 24 ... 16)
flexible:
without wire end ferrule
0.2 ... 1.5 mm
2
(AWG 24 ... 16)
with wire end ferrule, without plastic sleeve
0.2 ... 1.5 mm
2
(AWG 24 ... 16)
with wire end ferrule, with plastic sleeve
0.2 ... 1.5 mm
2
(AWG 24 ... 16)
Bare end 10 mm