Busserv er S7
L
70 Busserver S7 DE/EN 1.0
Communication
channel
PC interface PC interface
module
Transmission
medium
PLC interface module PLC interface Additional software required
IBHLink
Ethernet - Ethernet IBHLink adaptor cable
Ethernet/MPI
MPI
IBHNet (V1.1 or higher)
COMxMPI COMx - RS-232 PC adap ter RS-232/485 -
MPI Simatic
USB - USB PC adapter USB
Siemens communication driver
COMx - RS-232 PC adap ter RS-232/485
(V5.0 or higher)
PCI Siemens CP5611 MPI -
PCMCIA Siemens CP5511
Modem Teleservice Siemens
Teleservice a dapter
+ Siemens teleservice
(V5.0 or higher)
Ethernet - Ethernet IBHLink adaptor cable
Ethernet/MPI
+ IBHNet (V1.1 or higher)
PROFIBUS DP
COMx - RS-232 PC adap ter RS-232/485
PROFIBUS-CP Siemens communication driver
USB - USB PC adapter USB
(V5.0 or higher)
PCI Siemens CP5611 PROFIBUS -
PCMCIA Siemens CP5511
SOFTNET TCP/H1 Ethernet - Ethernet TCP/H1 -
Ethernet-CP
Siemens SOFTNET/SIMATICNET
(V3.0 or higher)
TCP direct Ethernet TCP -
Notes
COMxMPI ”x” stands for the number o f the COM port.
Use ”MPI Simatic” as communication channel if the Siemens c ommunication driver (V5.0 or higher) is installed on your PC or simultaneous access with
Lenze and Siemens software is required.
SOFTNET TCP/H1 Under normal circumstances, the TCP protocol is used. When using older CPs it may happen that only the Siemens H1 protocol is s upported. This is why
the bus server S7 also supports the H1 protocol.
TCP direct If the corresponding Siemens software is installed on y our PC, we recommend to use ”SOFTNET TCP/H1” as communication channel. Also use ”SOFTNET
TCP/H1” as communication channel if simultaneous access with Lenze and Siemens software is required.