5.3.2 STEP7 example programs
The following example programs are part of the bus ser ver S7 delivery package. They o nly differ in their
hardware configuration:
File name Hardware configuration
Ldsexmpl.arj/zip PLC S7-400 with CPU412-2DP
Ldsexmp2.arj/zip PLC S7-300 with CPU312-2DP and CP342-5
When the ”DriveServer with bus server S7” software is installed, the example programs are saved by
default in the directory:
C:\Programs\Lenze\DriveServer\S7
Tip!
If you want to use one of the example programs, adapt the hardware configuration to your system
environment.
Detailed i nformation on the creation of a STEP7 program can be found in chapter 5.6.
(^ 91)
Integration of an example program in the STEP7 environment:
1. Select File
WRetrieve in the S7 manager.
2. Select the corresponding file (Ldsexmpl.arj/.zip and / or Ldsexmp2.arj/.zip)inthe
sub-directory \S7 of the DriveServer installation.
3. Select the target directory.
(Normally, the sub-directory “\s7proj” of the STEP7 installation.)
Tip!
After retreiving the example project, you will be asked if the project is to be opened. If you answer this
question with no, the proje ct might not be added to the project list and must be opened later using the
Scan command.
5.3.3 Device description files for the Lenze drives
When the ”DriveServer with bus server S7” software is installed, the device description files of the
Lenze drives for PROFIBUS are saved by default in the directory:
C:\Programs\Lenze\DriveServer\GSD
Copy these data into the sub-directory ”\s7data\GSD” of the STEP7 installation.
Tip!
The latest versions of the GSD files are available on our Internet homepage: http://www.Lenze.de
under Service
WDownloadsWPROFIBUS.