6.6.5 Process data transfer
FC3, network 1
The following call is used to transmit two process data words (2PZD).
Process data word 1 is always the DRIVECOM control word.
Process da ta word 2 can be freely selected.
CALL FC 94
FirstDriveDW :=8
DriveSend_DB :=DriveSend_DB
DriveRecv_DB :=DriveRecv_DB
Enable :=Enable
QSP :=QSP
Reset :=Reset
Setpoint1 :=Setpoint1
ControlWord :=ControlWord
RDY :=RDY
TRIP :=TRIP
ActualValue1 :=ActualValue1
StatusWord :=StatusWord
The parameter FirstDriveDW defines the byte position of the first data word of the connected
drive controller.
For each drive controller, 8 data words are reser ved in the data blocks DriveSend_DB and /
or DriveRecv_DB. The first 4 data words are needed for parameter access and the last 4
data words for process data access.
The drive controllers must have successive I/O addresses.
The inputs Enable, QSP and Reset are set to enable the controller:
Enable =TRUE
QSP = FALSE
Reset = FALSE
The second process data word is assigned to the setpoint input.
Control word and sta tus word conform to the DRIVECOM spec ification.
The DRIVECOM status machine has already been implemented in FC94.
The outputs RDY and TRI P provide information about the controller status.
ActualValue1 is the value read out.
Tip!
Detailed information about the parameters of FC94 can be found in cha pter 6.3.7. (^ 107)
Use function block FC93 to transmit three process data words. (^ 106)