
Drive PLC Developer Studio
Appendix
15-21
l DDS EN 2.3
No. Possible remedyCause
41228
(A10C)
Incorrect interrupt Set a valid interrupt for the selected system bus adapter on the Settings tab.
41229
(A10D)
Incorrect baud rate Set a valid baud rate for the selected system bus adapter on the Settings tab.
41230
(A10E)
The drivers required f or the selected system bus adapter
were not found.
Reinstall the drivers for the selected system bus adapter.
41231
(A10F)
The system bus adapter is already used by another
application in an incompatible mode.
Close all applications and tr y again.
41232
(A110)
Error when loading the resources. Install the CAN driver update.
If the error still occurs, contact Lenze.
41233
(A111)
The configuration file could not be loaded. Reinstall the system bus default configuration.
41234
(A112)
Automation system read error. Reset the automation system (mains switching) and try again.
41235
(A113)
Error when reading f rom target system. Reset the target system (mains disconnection) and try again.
41236
(A114)
The maximum number of supported communication
modules (e. g., CAN USB adapters) was exceeded.
Remove one communication module.
41237
(A115)
The installed drivers do not support the selected system
bus adapter.
Install a driver update for the selected system bus adapter.
41238
(A116)
A system bus adapter unknown to the system has been
selected.
Install a driver update for the system bus adapter to be used.
41239
(A117)
System bus adapter initialization error. Check that the selected syst em bus adapter is connected properly to the PC.
41240
(A118)
Error when writing the configuration file. Reinstall the CAN driver.
41241
(A119)
The fo rmat of the configuration file is invalid. Reinstall the CAN driver .
41242
(A11A)
Several PC system bus adapters 2177 connected to the PC
at the same time.
Connect o nly the PC system bus adapter 2177 to be configured to t he PC.
41243
(A11B)
Error during USB device number write to PC system bus
adapter 2177.
Check that t he system bus adapter is the only PC system bus a dapter 2177 and properly
connected to the PC.
41244
(A11C)
Error during USB device number read from PC system bus
adapter 2177.
Check that t he system bus adapter is the only PC system bus a dapter 2177 and properly
connected to the PC.
41245
(A11D)
The file LSystembusL1.DLL could not be loaded. Reinstall the CAN driver.
41246
(A11E)
he file LSystembusL1.DLL could not be loaded. Install the CAN driver update.
If the error still occurs, contact Lenze
41247
(A11F)
The system bus adapter could not be initialized.
No free handles available..
Install the CAN driver update.
If the error still occurs, contact Lenze
41248
(A120)
The baud rate set for the selected system bus adapter does
not match the baud rate of the devices connected to the
bus.
Set the baud rate set for the bus devices for the selected system bus adapter on the
Settings tab.
41249
(A121)
The baud rate set for the selected system bus adapter does
not match the baud rate of the devices connected to the
bus.
Set the baud rate set for the bus devices for the selected system bus adapter on the
Settings tab.
41250
(A122)
Internal program error
Invalid filter setting.
Install the CAN driver update.
If the error still occurs, contact Lenze.
41251
(A123)
The parameter channel to be used is already used by
another bus station or by another PC program.
Set another parameter channel for the selected system bus adapter in the Settings index of
the system bus configurator or ensure that the selected parameter channel is not occupied
by another bus station or another PC program.
41252
(A124)
The LSystembusL2.DLL file could not be loaded. Reinstall the CAN driver update.
41253
(A125)
Error when starting the download mode. Restart the application.
41254
(A126)
Error during program download. Restart the application.
41255
(A127)
- -
41256
(A128)
Too many invalid telegrams have been detected on the
system bus.
Check the installation of the system bus (terminating resistor, shielding) for the baud rates
used.
41728
(A300)
Internal program error
OPC item could not be created.
Restart the application.
Comentarios a estos manuales