Lenze DDS v2.3 Manual de usuario Pagina 101

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 340
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 100
Drive PLC Developer Studio
Working with projects and objects
6-23
l
DDS EN 2.3
QSP Trip/CINH Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint Fail QSP is activated
Code C168, subcode 1
Error entry: none
CINH is activated
Code C168, subcode 1
Error entry: none
Motor continues running
Code C168, subcode 1
Error entry: none
Task overflo w Fail QSP is activated
Code C168, subcode 1
Error entry: Task overflow
CINH is activated
Code C168, subcode 1
Error entry: Task overflow
Motor continues running
Code C168, subcode 1
Error entry: none
Drive PLC
Automation system without drive function
Note!
The configuration of the digital outputs
remains unchanged with the extension modules.
remains unchanged with the Drive PLC.
QSP Trip/CINH Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint CINH is activated
Code C168, subcode 1
Error entry: none
Motor continues running
Code C168, subcode 1
Error entry: none
Task overflo w CINH is activated
Code C168, subcode 1
Error entry: Task overflow
Motor continues running
Code C168, subcode 1
Error entry: none
Show/Hide Bookmarks
Vista de pagina 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 339 340

Comentarios a estos manuales

Sin comentarios