Vista de pagina 26
Drive PLC Developer Studio
Program example
3-5
l DDS EN 2.3
14.Click behind the EQ box to select the output.
15.Select Insert
Assignment.
16.Change the text ??? at the output to GREEN.
STATE is compared to 1. If the result is TRUE, GREEN will be assigned.
This network will switch the traffic light to green if the status value input is 1.
The other traffic light colours RED, AMBER and OFF require three more networks.
17.Select Insert
Network (after) to create a new network.
18.Select Insert
Operator.
19.Click AND and change the text to OR.
20.Click behind the OR box to select the output.
21.Select Insert
Assignment.
22.Change the text ??? at the output to AMBER.
23.Select the upper input of the OR box and then Insert
Operator to insert another operator
before the selected input.