7 Remote maintenance and diagnostics
7.3 Computer access via Telnet
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3 Computer access via Telnet
Telnet is a standard mechanism for experts to change system settings.
Telnet ...
enables the access to the Controller data (example: Contents of the SD card);
requires an existing local connection or remote connection.
7.4 File transfer via FTP
The File Transfer Protocol (FTP) is a network protocol for the transfer of data within networks.
FTP makes it possible to exchange files between the controller and other PCs.
The controller data can be accessed via FTP connection.
FTP requires an existing connection or a remote connection.
In order to be able to transmit files with Windows via FTP, for example the Windows Explorer
which contains an implemented FTP support can be used.
Note!
Controller c300/p300:
These devices come with a deactivated Telnet in the Lenze standard setting.
The function can be activated via the »WebConfig«. The activation of the function can
influence the real-time behaviour.
After a restart of the Controller, the function is deactivated again.
Note!
FTP must be used for system-diagnostic purposes only. Deleting or changing system files
causes malfunctions of the controller!
Controller c300/p300:
These devices come with a deactivated FTP in the Lenze standard setting.
The function can be activated via the »WebConfig«. The activation of the function can
influence the real-time behaviour.
After a restart of the Controller, the function is deactivated again.
Further information relating to the function and configuration of FTP and web server/
»WebConfig« can be found in the reference manual:
Controller - Parameter setting & configuration